1948-1998, 50th Anniversary
Home
Site Map
Products & Literature
Applications
Partners
OEM Partners
Press Releases
Order Online
Request Information
Find My Rep
Contact Us
Trade Shows
Support Center
Rep Only Area
 

 
FOLLOW US:
YouTubeTwitterLinkedInFacebook
Raco Blog
Bookmark and Share

 

RACO Remote Alarms And Controls

RACO's Verbatim® Gateway keeps you in touch, and in control, no matter where you are.

The Verbatim® Gateway from RACO, the remote monitoring and alarm specialists, allows you to use TouchTone telephones anywhere as interactive, multi-functional operator interfaces. It's a unique breakthrough that provides convenient, inexpensive bidirectional communication with your PLC network via dial-up phone lines. So you can call in and check the status of any channel. Modify alarm criteria and monitoring points. Alter process variables and setpoints. So you can be called and receive clear voice message reports of alarm situations, with messages directed sequentially to as many as 16 phone numbers.

In a single, compact, ruggedly built system, the Verbatim® Gateway delivers these important functions and more. And it does so without requiring the use of PLC outputs or modification of PLC control programs.

In short, whether tracking or controlling intricate manufacturing processes or a host of water/wastewater treatment operations, the Verbatim® Gateway begins a new era by making remote communication with your PLC network easier and more affordable than ever.

Verbatim® Gateway

Unit of Measure

Specifications

# of Digital Alarm Inputs

N/A 4

# of Optional Digital Alarm Inputs

N/A 8 16 24 32

PLC Protocols

N/A DF1 & Modbus connection via RS-232 DH 485 via RS-485

# of Optional Analog Alarm Inputs

N/A 1 4 8 16

# of Optional Digital Outputs

N/A 4 8

Trade Name

N/A Verbatim® Gateway

Typical Monitoring Applications

N/A Boilers Chemical Plants Computer Rooms Facility Security Fish Hatcheries Frozen Food Storage HVAC Systems Hydroelectric Power Stations Pipeline & Compressor Stations Remote Pump Stations Storage Tanks Telephone Switchgear Unattended SCADA Systems Water & Wastewater Treatment Plants

Typical Sensors

N/A Flow Leak Level Motion pH Power Pressure Temperature Vacuum

Alarm Call Grouping

N/A Alarm calls to up to 16 phone number groups

Alarm Criteria

N/A Alarm on Closed Circuit Alarm on Open Circuit Run Time Meter Status only Totalizer

Alarm Reset

N/A ON/OFF

Alarm Reset Time

N/A 0.1 to 99.9 hours

Alarm System Enable/Disable

N/A Local and Remote Enable or Disable

Alarm Trip Delay

N/A 0.1 to 999.9 sec

Autocall Test

N/A ON/OFF

Autocall Time Interval

N/A 0.1 to 99.9 hours

Call Back/Call Forward

N/A Separate unique phone number

Dialing Format

N/A TouchTone or Rotary Pulse

# of Message Repetitions

N/A 1 to 20 repetitions

Phone Numbers

N/A 16 phone numbers up to 60 digits each

Read/Write Data Registers

N/A Any discrete or integer data register

Ring Delay

N/A 1 to 20 rings

Security Code

N/A 8 digits

Station ID & Message Recording Time

N/A User variable

Time Between Alarm Calls

N/A 0.1 to 99.9 min

# of Phone Numbers Dialed

N/A 16

Voice Recording Time

N/A 26 sec

FCC Registered

N/A Part 68, "Ringer Equivalence": 0.3A

Current Draw

N/A Standby 300 mA Operational 460 mA

PLC I/O Point Sensing

N/A Two RS232/RS485 ports

Accommodates

N/A Field-installed upgrades

Indoor Enclosure

N/A Rugged Metal

Communication Method

N/A Landline Wireless - Cellularm

Notification Methods

N/A PA System Pager Voice Call

Optional I/O

PLC Addresses

N/A 96

Electrical

Power Requirement

N/A 105-135 VAC, 50/60 Hz, 15 watts maximum or 8-14 VDC at 500 mA maximum.

Battery Charging

N/A Precision voltage controlled, including automatic rapid recharge after drain.

Battery Backup Time

N/A 13 hours

Input Sensing

N/A Four unpowered contact inputs standard. Open contacts see 5 volts DC; closed contacts see 10 ma DC.

Printer Port

N/A Standard Centronics Parallel

Physical

Surge Protection

N/A Integral gas tube and solid-state protectors on all phone, power, and signal lines.

Weight

N/A 8 lbs

Height

N/A 11 7/8 in.

Width

N/A 9 3/4 in.

Depth

N/A 5 in.

Mounting Centers

N/A 11 3/8" vertical x 6" horizontal

Environmental

Temperature Range

N/A 20 to 130 ºF

Humidity

N/A 0 to 95%, Non-condensing

Telephone

N/A

  • Rotary pulse or tone dialing, keyboard selectable.
  • Dials up to 16 different numbers, each up to 60 digits long.
  • Allows programming of multiple PBX delays in 1-second increments.
  • FCC Registered Part 68, "Ringer Equivalence": 0.3A.
  • Alarm Ack

Speech Messages

Speech Messages

N/A Users record their own messages. Also includes resident vocabulary for programming guidance and for default "alarm/normal" speech if no user messages are recorded.

UL Standard

UL Standard

N/A Verbatim® complies with UL Standards: 1459, 1950

Warranty

Warranty

N/A 5 years

PLC Communication

N/A

  • Fully Compatible: Requires no modifications to existing network configuration, PLC wiring or programs.
  • Remote Data Table Access: Monitor or alter any data table location on demand via front panel or telephone.
  • System Security: Access protected by security codes.
  • Alarm Monitoring: Continuously monitors 32, 64 or 96 PLC addresses.
  • Gateway Function: Provides for exchange of data between PLC devices on incompatible networks.
  • I/O Export: Able to continuously transfer internal I/O and alarm data to remote PLCs.
  • Supported Protocols: Modbus Plus, Modbus RTU, Allen-Bradley DFl, and Allen-Bradley DH485 (programming port).
  • Latency: Depends on configuration and other Network traffic. Typical range. 01-10 seconds.

Internal I/O Options

N/A

  • Analog. Custom scaled in the units of measurement required for your job. Analog alarms on a high and a low alarm setpoint. Upgradeable to 1, 4, 8, or 16 analog channels.
  • Remote Supervisory Control. The operator can turn equipment on or off via any telephone. Upgradeable to 4 or 8 outputs.
  • Channels. Upgradeable to 8, 16, 24,or 32 contact channels.

Factory Options

N/A

  • Enclosure. System available in NEMA 4X enclosure, which is corrosion proof and sealed against 12 feet of water.
  • Environmental. Thermostatically controlled heater available, suggested for operation below 20ºF or where condensation may occur.
  • Local Alarm Relay Output. Relay activates during unacknowledged alarm conditions.

Extended Functionality and Versatility - At Minimal Cost.

N/A Continuous real-time communication between the Verbatim® Gateway and the PLC network is performed via a serial link using the protocols supported by specific PLC models. Any PLC's I/O points and data table locations can be manually altered. In addition, the system provides automatic monitoring of as many as 96 points - points reflecting any combination of discrete, analog, timer, counter, or other PLC data objects.

Further, the Verbatim® Gateway uses only a single cable connection, to deliver its extensive functionality. You avoid the burdensome costs of complex wiring, additional PLC outputs and relays. You add monitoring points at costs that are about 40% less than those associated with traditional PLC-to-input configurations. As a result, you’re able to fully utilize the potential of your PLCs - easily and inexpensively.

Simultaneous Monitoring of Multiple PLCs on Multiple Networks - Even on Networks with Dissimilar Protocols.

N/A The Verbatim® Gateway is designed for use with popular network protocols - including the Modicon Modbus Plus™ Modbus® RTU and the Allen Bradley DH485. Operating at selectable communication speeds up to 1 Mbaud, it's even capable of simultaneously monitoring PLCs on networks using different protocols. And all protocol-specific error detection techniques and retransmission methods are fully maintained. You can also use the Verbatim® Gateway as a bridge between incompatible networks, so that data can be exchanged between them.

Fast Access From Any TouchTone Phone Using Brief 4-Digit Codes, Easy Programming Guided by Clear Voice Prompts.

N/A Accessing any of the 96 points which are automatically controlled by the Verbatim® Gateway requires only a brief 4-digit sequence. Users can quickly perform functions that range from ordinary status-checking and message recording/review/revision to reading/writing of data registers at any network address and selection of global commands applying to all channels. Responses are always in voice format; data register numeric codes, for example, are converted to spoken voice messages. If a programming sequence is not recognized by the Verbatim® Gateway or if an invalid parameter is entered, the system responds with the appropriate voice message. The clear voice guidance simplifies entry of dial-out phone numbers, recording of alarm messages and setting of trip delays. The system’s preprogrammed operating parameters streamline set-up, yet they may be easily altered to meet specific needs.

The Verbatim® Gateway Makes Certain No Alarm Condition Goes Unheeded or Unacknowledged.

N/A When an alarm condition occurs, the Verbatim® Gateway automatically dials up to 16 field-programmable phone numbers - numbers having as many as 60 digits each. The system then reports the station indenfication and the specific alarm condition. Acknowledgment of an alarm phone call is effected by the simple touch of a button on the called phone during the alarm notification or by calling the reporting unit after the call has been received.

Complete Status Reports - Always at Your Fingertips.

N/A Wherever there's a telephone, there's instant access to status reports on all conditions monitored via the Verbatim® Gateway. Similarly, the touch of a telephone key lets you review and alter programming, change alarm criteria, monitoring points, process variables, and setpoints. Further, the system’s built-in microphone permits listening to on-site sounds, and a built-in speakerphone allows convenient communication with on-site personnel.

Unlimited Flexibility in Stored Messages - Each Delivered with Max. Clarity.

N/A Free of the restrictions imposed by built-in vocabularies, the Verbatim® Gateway can store in memory anything that can be spoken - from names and numbers to technical terms and detailed instructions.

The system's advanced digitized voice technology accurately replicates the original speaker. So there’s less opportunity for misunderstanding or error. And messages can easily be changed or entered via the front panel or remotely from any TouchTone telephone.

Designed and Built For Reliable Operation in The Harshest Industrial Environments.

N/A The Verbatim® Gateway's heavy duty metal enclosure, carefully selected and proven solid-state components, and sealed membrane keyboard are an assurance of problem free performance year after year.

In the event of a power failure, a rechargeable gel-cell battery maintains full and continuous operation for up to thirteen hours. Further, because a precision regulated charger is used instead of a traditional "trickle" charger, battery charging time is minimized and battery life significantly extended.

The Verbatim® Gateway also employs non-volatile memory, so no reprogramming is needed following power outages. Alarm messages and user-entered programming are retained for years-even in the total absence of power to the system.

Continuous Self-Diagnostics, Automatic Alarming in The Event of A PLC Communication Problem.

N/A The Verbatim® Gateway is self testing and provides complete diagnostic information. Should it detect a communication failure, the unit automatically initiates an alarm. In addition to generating voice message calls, alarm situations are also indicated by the system's LED display panel.

With start-up and operation made quick and easy through default settings and voice prompts, the Verbatim® Gateway places comprehensive PLC monitoring and control capabilities as close as the nearest TouchTone telephone. Based on the Verbatim® Automatic Dialing Remote Monitoring System-field proven by thousands operating worldwide - it's the "single-package" solution for keeping your fingers on the pulse of your PLC-controlled processes, for accessing and altering those processes from anywhere in the world.

View PDF Brochures

Options

Power / Telephone Line Conditioners

N/A , 120VAC Power Conditioner ($146.00)
, Analog Telephone Line Surge Protector ($146.00)

Call Toll Free-800-722-6999


Copyright © 1998-2020 RACO Mfg. & Engineering Co., Inc. All rights reserved. User Agreement and Privacy Policy statements.

alarmagent.com