Items |
![]() 300VSS-4C Verbatim® VSS-4C Autodialer List Price $2,095.00
|
![]() 301VSS-8C Verbatim® VSS-8C Autodialer List Price $2,350.00
|
![]() 302VSS-16C Verbatim® VSS-16C Autodialer List Price $3,250.00
|
![]() 303VSS-24C Verbatim® VSS-24C Autodialer List Price $3,895.00
|
![]() 304VSS-32C Verbatim® VSS-32C Autodialer List Price $4,650.00
|
|||||
# of Digital Alarm Inputs | N/A 4 | N/A 8 | N/A 16 | N/A 24 | N/A 32 | |||||
# of Optional Digital Alarm Inputs | N/A 8 16 24 32 | N/A 16 24 32 | N/A 24 32 | N/A 32 | N/A | |||||
# of Optional Analog Alarm Inputs | N/A 1 4 8 16 | |||||||||
# of Optional Digital Outputs | N/A 4 8 | |||||||||
# of Optional PLC Addresses | N/A 32 64 96 | |||||||||
PLC Protocols | N/A DF1 & Modbus connection via RS-232 [optional] | |||||||||
Verbatim SCADA Compatibility | N/A Compatible with RACO SCADA software | |||||||||
# of Phone Numbers Dialed | N/A 16 | |||||||||
Voice Recording Time | N/A 26 sec | N/A 26 sec | N/A 52 sec | N/A 78 sec | N/A 104 sec | |||||
FCC Registered | N/A Part 68, "Ringer Equivalence": 0.3A | |||||||||
Alarm Call Grouping | N/A Alarm calls to up to 16 phone number groups | |||||||||
Alarm Criteria | N/A Alarm on Closed Circuit Alarm on Open Circuit Run Time Meter Status only Totalizer | |||||||||
Alarm Reset | N/A ON/OFF | |||||||||
Alarm Reset Time | N/A 0.1 to 99.9 hours | |||||||||
Alarm System Enable/Disable | N/A Local and Remote Enable or Disable | |||||||||
Alarm Trip Delay | N/A 0.1 to 999.9 sec | |||||||||
Autocall Test | N/A ON/OFF | |||||||||
Autocall Time Interval | N/A 0.1 to 99.9 hours | |||||||||
Call Back/Call Forward | N/A Separate unique phone number | |||||||||
Dialing Format | N/A TouchTone or Rotary Pulse | |||||||||
# of Message Repetitions | N/A 1 to 20 repetitions | |||||||||
Phone Numbers | N/A 16 phone numbers up to 60 digits each | |||||||||
Ring Delay | N/A 1 to 20 rings | |||||||||
Security Code | N/A 6 digits | |||||||||
Station ID & Message Recording Time | N/A User variable | |||||||||
Time Between Alarm Calls | N/A 0.1 to 99.9 min | |||||||||
Current Draw | N/A Standby 300 mA Operational 460 mA | |||||||||
Accommodates | N/A Field-installed upgrades | |||||||||
Indoor Enclosure | N/A Rugged Metal | |||||||||
Trade Name | N/A Verbatim® | |||||||||
Typical Monitoring Applications | N/A Boilers Chemical Plants Computer Rooms Facility Security Fish Hatcheries Frozen Food Storage HVAC Systems Hydroelectric Power Stations Pipeline & Compressor Stations Remote Pump Stations Storage Tanks Telephone Switchgear Unattended SCADA Systems Water & Wastewater Treatment Plants | |||||||||
Typical Sensors | N/A Flow Leak Level Motion pH Power Pressure Temperature Vacuum | |||||||||
Power Requirement | N/A 105-135 VAC, 50/60 Hz, 15 watts maximum or 8-14 VDC at 500 mA maximum. | |||||||||
Battery Charging | N/A Precision voltage controlled, including automatic rapid recharge after drain. | |||||||||
Battery Backup Time | N/A 20 hours | |||||||||
Input Sensing | N/A Four unpowered contact inputs standard. Open contacts see 5 volts DC; closed contacts see 10 ma DC. | N/A Eight unpowered contact inputs standard. Open contacts see 5 volts DC; closed contacts see 10 ma DC. | N/A Sixteen unpowered contact inputs standard. Open contacts see 5 volts DC; closed contacts see 10 ma DC. | N/A Twenty-four unpowered contact inputs standard. Open contacts see 5 volts DC; closed contacts see 10 ma DC. | N/A Thirty-two unpowered contact inputs standard. Open contacts see 5 volts DC; closed contacts see 10 ma DC. | |||||
Printer Port | N/A Standard Centronics Parallel | |||||||||
Surge Protection | N/A Integral gas tube and solid-state protectors on all phone, power, and signal lines. | |||||||||
Weight | N/A 8 lbs | |||||||||
Height | N/A 11 7/8 in. | |||||||||
Width | N/A 9 3/4 in. | |||||||||
Depth | N/A 5 in. | |||||||||
Temperature Range | N/A 20 to 130 ºF | |||||||||
Humidity | N/A 0 to 95%, Non-condensing | |||||||||
Speech Messages | N/A Users record their own messages. Also includes resident vocabulary for programming guidance and for default "alarm/normal" speech if no user messages are recorded. | |||||||||
UL Standard | N/A Verbatim® complies with UL Standards: 1459, 1950 | |||||||||
Warranty | N/A 5 years | |||||||||
Mounting Centers | N/A 11 3/8" vertical x 6" horizontal | |||||||||
Features |
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
|||||
Telephone |
N/A
|
|||||||||
Modular Options |
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
|||||
Factory Options |
N/A
|
|||||||||
Alarm Autodialing |
N/A
The system is designed to continuously monitor preset alarm points. If an alarm condition is sensed at a monitored point, the Verbatim System will automatically dial a list of 16 pre-programmed emergency telephone numbers, calling until it gets an answer. When the call is answered and acknowledged, the system reports the alarm location and status via pre-recorded voice messages. Communicating over standard land- line or wireless telephone networks, the Verbatim® delivers alarm messages to standard phones, cell phones, numeric or voice pagers, and voice mail systems, and talks just as easily with computers. |
|||||||||
User-Recorded Messages | N/A The voice messages are digitally pre-recorded by the user. Anything that can be spoken is accurately stored in memory from names and numbers to technical terms and detailed instructions. Messages are delivered with maximum clarity, lessening the chance for misunderstanding or error. And, you can easily enter or change your messages over the phone or at the front panel. | |||||||||
A Fully Interactive System |
N/A
With Verbatim®, you’re never out of touch with your monitoring system. With any standard touch-tone phone, you can call in for a status report, review and change programming, or control a remote device. With the touch of a key, you can listen to local sounds or talk to personnel using the unit’s built- in speaker phone. When calling for status report you hear a comprehensive summary of all conditions monitored by the system, including internal power. Hard copies of event data alarms, acknowledgements, inquiries, and programming changes can be printed out at any time using the system’s data logging capabilities. Controls and indicators are provided on the Verbatim® front panels for on-site programming and review of system operation, alarm status, and battery condition. |
|||||||||
Supervisory Control System | N/A A Verbatim® System can be equipped with up to 8 digital control outputs to remotely actuate HVAC systems, pumps, compressors, and other electrical devices from a standard phone, the Verbatim® front panel, or a PC. | |||||||||
SCADA System | N/A RACO MMI/SCADA Systems provide monitoring and control of up to 200 RACO Verbatim® Remote Terminal Units (RTUs) over the standard dial-up telephone network. Each RTU has full alarm monitoring, reporting, and autodialing capabilities, and because Verbatim® systems report by exception, they do not need to be polled. When an alarm is sensed, the RTU reports to the central computer. If the computer operator does not acknowledge the alarm, the RTU will commence autodialing. | |||||||||
PLC Network Interface | N/A Offering alarm and monitoring for as many as 96 remote channels, the Verbatim® can use RS232 communications to work with any PLC or other device using Modicon's Modbus protocol. | |||||||||
Take Control of Remote Equipment | N/A A Verbatim® System can be used with a RACO Responder or another Verbatim® to actuate pumps, compressors, gates, or other electrically operated equipment over the dial-up telephone network. Upon receipt of an alarm signal low water level, for example the Verbatim® issues a command to activate an output relay in the Responder or other Verbatim® unit, which initiates an action such as turning on a pump motor. | |||||||||
Memory Retained During Power Failure | N/A Verbatim® systems incorporate a non-volatile memory. Recorded alarm messages and user-entered programming is retained indefinitely in the event of a power loss. | |||||||||
Battery Backup for Safety | N/A A rechargeable gel cell battery provides up to 20 hours of continuous operation in the event of power loss. And because the system uses a precision regulated charger instead of the traditional "trickle" charger, the time required for charging is minimized and battery life is significantly extended. | |||||||||
Built for Long Term Survival in The Toughest Environments | N/A Verbatim® is designed and built for superior performance year after year. The system's rugged durability is evident in its heavy-duty metal enclosure, carefully selected and proven solid state components, and sealed membrane keyboard. Heavy-duty solid-state and gas tube surge protection is provided on all power, phone, and signal lines. | |||||||||
Options |
N/A
Analog Signal Input Monitoring Option Data Communications Option Digital Input Monitoring Option Modbus Interface Option Remote Supervisory Control Option Verbatim Responder |
|||||||||
Specifications |
N/A
Dialer Specifications - Verbatim Model DSP |
|||||||||
Application Bulletin |
N/A
Chemical Distributors Monitor Customer Inventory Levels with RACO Verbatim Systems Closed-Loop Control System for Remote Facilities Dallas Aquarium Increases Animal Protection National Energy Group Application Presentation New England Small water system implements 24-hour monitoring RACO Central Watchdog System Automatically Verifies Phone Line and Autodialer Operation |
|||||||||
Communication Method | N/A Landline Wireless - Cellularm | |||||||||
Notification Methods | N/A PA System Pager Voice Call | |||||||||
Read/Write Data Registers | N/A Any discrete or integer data register [optional] | |||||||||
PLC I/O Point Sensing | N/A Two RS232/RS232 ports [optional] | |||||||||
Power / Telephone Line Conditioners |
N/A
999ACPC, 120VAC Power Conditioner ($146.00) 999TPC, Analog Telephone Line Surge Protector ($146.00) |
|||||||||
|